token backup update firmware
Update the firmware on a Luna Backup HSM, using a firmware update package available on the Luna Network HSM 7 appliance. The package must be transferred to the appliance by pscp/scp (individually or as a component of a system update), and you must log in to the Backup HSM as HSM SO (using the token backup login command) before the token backup update firmware command is run. The command requires no package name.
Before you can use this command, you must acquire the firmware update file from Thales and send the file to the Luna Network HSM 7 (using pscp or scp)
NOTE Firmware update is a local operation only, and is not supported remotely.
A capability update or a firmware update is meant to be applied just one time to an HSM. If you attempt to re-apply a capability update to an HSM that already has the capability installed, the system throws an error like " C0000002 : RC_GENERAL_ERROR ". A similar result occurs if you attempt to install a particular firmware update more than once on one HSM. This is expected behavior.
User Privileges
Users with the following privileges can perform this command:
>Admin
>Operator
Syntax
token backup update firmware -serial <serialnum> [-force]
Argument(s) | Shortcut | Description |
---|---|---|
-force | -f | Force the action without prompting. |
-serial <serialnum> | -s | Specifies the token serial number. |
Example
lunash:>token backup update firmware -serial 496771 CAUTION: This command updates the Token firmware. This process cannot be reversed. Type 'proceed' to continue, or 'quit' to quit now. >proceed Success Firmware updated. Command Result : 0 (Success)