Home > |
---|
The SafeNet Network HSM front-panel LCD provides system status summary information, for example:.
Ver:6.0.0-xx
ISO 60
The top line of the display cycles through the current software version, followed by the currently assigned network interface device addresses. The bottom line shows the current system status (see table below). If there are no faults detected, the display indicates that the appliance is in service, condition code 0 (ISO 0). If one or more fault conditions have been detected, the display shows the most severe, until that condition has been corrected, then it displays the next most severe condition, until all errors have been corrected.
Note: Not all faults are serious. Some might merely indicate that an available service is not running because you chose not to run it.
The displayed messages update following a scan of selected system conditions, approximately every 15 seconds. Therefore, if you have fixed a condition that caused an error, the display should clear the error indication within seconds. If the display continues to show the error message, then the condition may have re-occurred and you should investigate. The display summarizes the information that you can retrieve using various "show" commands in the SafeNet Shell (lunash).
The following codes are currently implemented:
Condition Type |
Code |
Meaning |
LunaSH command equivalent |
---|---|---|---|
ISO |
0 |
In service Okay, no trouble |
n/a |
55 |
In Service Okay, eth0 is offline. Please run 'network show' and 'service status network’ for more information |
network show |
|
60 |
In Service Okay, eth1 is offline. Please run 'network show' and 'service status network' for more information. |
network show |
|
100 |
In Service Okay, SNMP subsystem is not running. Please run "service status snmp" for more information. |
service status snmp |
|
OOS |
20 |
Out of Service - Please run "service status ntls" for more information. Note: Both the NTLS and STC services must be running for the appliance to be in service. |
service status ntls |
25 |
Out of Service - NTLS is not bound to an ethernet device. Please run "service status ntls" and "syslog tail" for more information |
service status ntls |
|
30 |
Out of Service - HSM subsystem has experienced one or more critical events. Please run "hsm information show" and "syslog tail" for more information. |
hsm information show hsm show |
|
80 |
Out of Service - Please run "service status stc" for more information. Note: Both the NTLS and STC services must be running for the appliance to be in service. |
service status stc | |
OFL |
50 |
Off Line - Neither ethernet interface is connected to the network. Please run "network show" command and "syslog tail" for more information. |
network show |
IST |
70 |
In Service with Trouble - The syslog subsystem is not running. Please run "service status syslog" and "syslog tail" for more information. |
|
90 |
In Service with Trouble - SSH ( secure shell ) subsystem is not running. Please run "service status ssh" and "syslog tail" for more information. |
service status ssh |
|
110 |
In Service with Trouble - Hard disk utilization is too high. Please run "syslog tarlogs" and then scp to remove older log files |
status disk |
The front-panel displays two lines of 16 characters. When no error conditions are detected (in service okay), the display cycles through the network interface devices, showing the hostname and IP address of each device. Because the display width is limited to sixteen characters, some information may span both lines, especially information text at appliance power up. For the service status information, the LCD scrolls the codes if there are more than can fit on a single line (e.g., OFL 50,20,100, OFL 50,20,100,55, OFL 20,100,55,60 OFL 100,55,60 ).
System State | Expanded Description |
---|---|
ISO |
In this service state the appliance is online and the necessary subsystems are operational. The appliance is providing encryption/signing services as expected. |
IST |
In this service state the appliance is online and the necessary subsystems are operational. The appliance is able to provide encryption/signing services but not necessarily to the fully expected level. |
OFL |
In this service state the appliance is not currently connected to the ethernet network and cannot provide service. |
OOS |
In this service state the appliance is online but the necessary subsystems are NOT operational. The appliance is NOT providing service. |