Home > |
---|
HKEY_LOCAL_MACHINE\SOFTWARE\SAFENET\ProtectToolkit M\debugLevel
REG_DWORD
Valid values are 0 through 5. If turned on, debug output is saved in the ptkm.log file in the root directory of the current drive. Each level includes the output of all preceding levels.
•0: no debug output
•1: log the invocation of CSP related methods and if an error occurs, their return code
•2: Internal errors are converted to NTE_SYS_FAIL. This debug level logs the internal error at the point of conversion.
•3: CSP function input and output parameters - but NOT user related data (such as encrypted or clear text, or data to hash).
•4: Other information not covered by the preceding levels - but NOT user related data.
•5: Lists the Cryptoki function calls, by name only.
Note that the debug level is read when a process loads the SafeNet ProtectToolkit-M library file. This means that in order to change the debug level, you must first stop any SafeNet ProtectToolkit-M applications.
The log file ptkm.log is cleared during initialization of the SafeNet ProtectToolkit-M library.