Installing the Luna USB HSM 7 Hardware
This section describes how to connect the Luna USB HSM 7 to a client computer.
Prerequisites
>Ensure that the Luna HSM Client software with the USB option is installed on the client (see Luna HSM Client Software Installation). This includes the necessary device drivers.
NOTE If you are installing Luna HSM Client on Windows, the driver may not be installed unless the Luna device is connected to the computer first; refer to Backup/USB/PCIe Drivers Not Installed on Windows 10 or Windows Server 2022 Unless Device is Connected.
To connect the Luna USB HSM 7 to a client
1.Use the included USB-C to USB cable to connect the Luna USB HSM 7 to a USB port on the client computer.
NOTE On most Luna HSM Client computers, the USB port provides adequate power, and connecting the provided power supply is not recommended. Wait and confirm that the HSM boots properly. If the HSM fails to boot up:
1. Disconnect the HSM from the USB port.
2. Connect the HSM to power using the provided power supply. Wait for it to boot completely.
3. Reconnect the HSM to the USB port on the client.
If the HSM is connected to the USB port before the power supply, you may encounter an issue where the HSM occasionally loses contact with the client, and must be power cycled.
2.Run LunaCM on the client computer to ensure the Luna USB HSM 7 is visible to the client.
Available HSMs: Slot Id -> 4 Label -> Serial Number -> 556677 Model -> Luna G7 Firmware Version -> 7.7.2 Bootloader Version -> 1.6.0 Configuration -> Luna HSM Admin Partition (PW) Key Export With Cloning Mode Slot Description -> Admin Token Slot HSM Status -> L3 Device, Zeroized Current Slot Id: 4