Luna Network HSM Required Items

This section provides a list of the components you should have received with your Luna Network HSM order. The specific items you received depend on whether you ordered a password-authenticated or a PED-authenticated Luna Network HSM, and whether your order included a backup device or other options as described below.

Basic Luna Network HSM order items

The standard items that you should have received as your basic order for a Luna Network HSM are:

Qty Item

1

Luna Network HSM Appliance

Your order should include one password-authenticated or PED-authenticated Luna Network HSM. The different HSM models appear physically identical.

2

Power Supply Cord

REQUIRED, NOT INCLUDED. You must provide one for each power supply, with connectors appropriate to your region of operation, usually sold separately(*).

1

Adapter Cable: RJ45 to USB with a standard eight-pin, eight connector (8P8C) modular connector

Used to open a terminal connection to the HSM during initial configuration.

1

Front Ear Bracket Set

Set includes:

>(2) front ear brackets

>(4) bracket screws

1

Friction Rail Mounting Bracket Set

The standard mounting bracket set is designed for use in standard 483mm (19")-wide racks with depth of 620-902mm (24.5”-35.5”). See Using the Supplied Mounting Brackets for installation instructions. Set includes:

>(2) side rails

>(8) side rail screws

>(2) sliding rear brackets (fit into the rails for rear support adjustable positioning)

CAUTION!   The included mounting hardware is meant for static positioning of the appliance. The long tab that slides into the bracket, applied to each side of the appliance, is adjustable for fitting the appliance into racks of depth - it must not be used to extend the appliance out of the rack.

Optional sliding rails with rolling bearings are available for situations where rolling excursion of the appliance, while attached to the rack, is required for maintenance. See Optional Items.

1

Friction Rail Rack Mounting Screws/Cage Nuts

Set includes:

>(8) M5 cage nuts

>(8) M5x14 rack screws

If you did not receive this set, you can request one from Thales (part number: 216-000035-001) or obtain your own suitable screws/nuts.

1

Secure Locking Bezel

For maximum physical security, this faceplate bezel can restrict access to the Luna Network HSM's front-facing inputs. Includes set of three (3) keys for each lock (locks are keyed differently).

(* We have generally discontinued including power cords with HSM appliances because so many are wasted. Many customers reship our products to labs and data centers all over the world, and the correct format power cord is readily and economically sourced at the destination. )

PED-Authenticated Luna Network HSM order items

If you ordered a PED-authenticated Luna Network HSM, you should have received some combination of the following items in addition to the items in the basic order.

Note that you can use PED keys that you already own and use with other HSMs -- PED keys can be used with multiple HSMs if that is appropriate in your context. You should purchase the number of PEDs you need for your own convenient operation, and for backup/standby units as your security policies might require.

Qty Item
1+

Standard or Remote-Capable Luna PED

Your order should include at least one PED device.

If you intend to back up your Luna Network HSM to a Luna Backup HSM, then you require a Luna PED to connect to that Backup HSM.

If you intend to combine remote operation and backup, you might prefer to have a second PED. It is possible to use a single Luna PED for both connections, and to simply change between local and remote mode as needed.

Note that you can use PED keys that you already own and use with other HSMs if appropriate. You should purchase the number you need for your own convenient operation, and for backup/standby units as your security policies might require.

1

Luna PED cable

The PED device connects to your HSM using a Type A to Mini B USB cable .

1

Luna PED Power Supply Kit

If you ordered a Luna PED, your order should include a Luna PED power supply kit with the appropriate connection for your region. The power supply is auto-sensing and includes replaceable mains plug modules for international use.

1

Set of PED Keys and Labels

Your order should include a set of iKey PED keys and peel-and-stick labels.

Optional Items

You may have also ordered one or more of these optional items:

Qty Item
1

Sliding Rail Mounting Bracket Set

     

The sliding rail system is designed for use in standard 483mm (19")-wide racks with depth of 620-902mm (24.5”-35.5”). The sliding rail mounts allow for easy removal and access to the rear face of the HSM. See Using the Optional Sliding Rail System for installation instructions. The set includes:

>(2) sliding rail mounts with removable side rails

>(2) transformer brackets

>(6) rail screws

1

Sliding Rail Rack Mounting Screws

Set includes:

>(8) M5x8 flat-headed screws

If you did not receive this set, you can request one from Thales (part number: 216-000034-001) or obtain your own suitable screws. If you do not use the screws included in this kit, ensure that the screw heads are flat enough so as not to interfere with the locking bezel.

1

Luna G7 Backup HSM B700/B750/B790

You can back up your selected Luna Network HSM partition contents (root keys, certificates, other items) to a Luna Backup HSM. The Luna Backup HSM is suitable for off-site storage and for backing up multiple HSM partitions. It can back up contents of password-authenticated or of PED-authenticated HSMs.

Refer to Backup and Restore Using a Luna Backup HSM (G7).

2

SFP 10 Gbps Optical Ethernet transceiver modules

   

If you ordered the 10 Gbps Optical Ethernet option, two of the RJ45 ports on the appliance are replaced by SFP+ connectors (protected by dust covers during shipping). The SFP 10G Optical transceiver modules are packed separately, within the appliance packaging, and must be inserted in the appliance before use.