lunareset
The lunareset utility allows you to reset an HSM that has become unresponsive, without having to reboot the host computer. This command does not affect the contents of the HSM.
NOTE On Linux clients, lunareset is installed in the /usr/safenet/lunaclient/sbin directory.
Syntax
Linux | lunareset <dev_path> [-F | --function-level-reset] [-h | --help] [-v | --verbose] |
Windows | lunareset <dev_path> [-h|--help] [-v| --verbose] |
Argument(s) | Description |
---|---|
-F | --function-level-reset |
Perform a function-level reset. This option resets only a specific function running on the card - it does not reset the entire card. Note: This option is reserved for use in a future release. Use only under the direction of Technical Support. |
-h | --help | Display usage instructions for the lunareset command. |
-v | --verbose | Display additional operating information. |
<dev_path> |
Specify the path to the device you wish to reset, as follows: Windows: >k7pf0 - reset the first Release 7.x SafeNet Luna PCIe HSM installed in the host computer. >viper0 - reset the first Release 6.x (or earlier) SafeNet Luna PCIe HSM installed in the host computer. >lunauhd0 - reset the first SafeNet Luna USB HSM installed in the host computer. Linux: >/dev/k7pf0 - reset the first Release 7.x SafeNet Luna PCIe HSM installed in the host computer. >/dev/viper0 - reset the first Release 6.x (or earlier) SafeNet Luna PCIe HSM installed in the host computer. >/dev/lunauhd0 - reset the first SafeNet Luna USB HSM installed in the host computer. NOTE If you have multiple devices installed in the host computer, you will need to determine the device path before using this command. |
Example
LunaCM v7.0.0 - Copyright (c) 2006-2017 Gemalto Available HSMs: Slot Id -> 0 Tunnel Slot Id -> 4 Label -> mypcie7par Serial Number -> 349297122736 Model -> Luna k7 Firmware Version -> 7.0.0 Configuration -> Luna User Partition With SO (PED) Signing With Cloning Mode Slot Description -> User Token Slot Slot Id -> 1 Tunnel Slot Id -> 4 Label -> mypcie7 Serial Number -> 150022 Model -> K6 Base Firmware Version -> 7.0.0 Configuration -> Luna HSM Admin Partition (PED) Signing With Cloning Mode Slot Description -> Admin Token Slot HSM Configuration -> Luna HSM Admin Partition (PED) HSM Status -> OK Current Slot Id: 0 lunacm:> exit c:\Program Files\SafeNet\LunaClient> lunareset.exe /dev/k7pf0 c:\Program Files\SafeNet\LunaClient>