pedclient mode start

Starts up the PED Client.

Syntax

pedclient mode start [-winservice] [-eadmin <0 or 1>] [-idletimeout <int>] [-socketreadtimeout <int>] [-socketwritetimeout <int>] [-shutdowntimeout <int>] [-pstartuptimeout <int>][-pshutdowntimeout <int>] [-logfilename <filename>] [-loginfo <0 or 1>] [-logwarning <0 or 1>] [-logtrace <0 or 1>] [-maxlogfilesize <size>] [-locallogger]

Option Description
-winservice Starts the PED Client for Windows service. The standard parameters used for pedclient mode start can be used for pedclient mode start -winservice as well.
-eadmin <0 or 1>

Optional. Specifies if the administration port is on "localhost" or on the external host name.

-idletimeout <int> Optional. Specifies the idle connection timeout, in seconds.
-socketreadtimeout <int> Optional. Specifies the socket read timeout, in seconds.
-socketwritetimeout <int> Optional. Specifies the socket write timeout, in seconds.
-shutdowntimeout <int> Optional. Specifies the shutdown timeout for internal services, in seconds.
-pstartuptimeout <int> Optional. Specifies the startup timeout for the detached process, in seconds.
-pshutdowntimeout <int> Optional. Specifies the shutdown timeout for the detached process, in seconds.
-logfilename <filename> Optional. Specifies the log file name to which the logger should log messages.
-loginfo <0 or 1> Optional. Specifies if the logger should log "info" messages. Set to 0 for no, 1 for yes.
-logwarning <0 or 1> Optional. Specifies if the logger should log "warning" messages. Set to 0 for no, 1 for yes.
-logerror <0 or 1> Optional. Specifies if the logger should log "error" messages. Set to 0 for no, 1 for yes.
-logtrace <0 or 1> Optional. Specifies if the logger should log "trace" messages. Set to 0 for no, 1 for yes.
-maxlogfilesize <size> Optional. Specifies the maximum log file size in KB.
-locallogger Optional. Specifies that the Remote PED logger should be used, not the IS logging system.

Example

C:\Program Files\Safenet\LunaClient>pedClient –mode start