Home >

LunaCM Command Reference Guide > LunaCM Commands > ped > ped set

ped set

Configure a default IP address and/or port that are used by the ped connect command when establishing a connection to a Remote PED Server. See ped connect for more information.

Syntax

ped set {[-ip <ped_server_ip>] | [-port <ped_server_port_number>]}

Parameter Shortcut Description
-ip -i <ped server ip>

Specifies the default IP Address used by the ped connect command.

-port -p <server port num>

Specifies the default port used by the ped connect command.

Range: 0-65535
Default: 1503

Example

lunacm:>hsm ped set -ip 106.55.19.59 -port 3456
 
Command Result : 0 (Success)
 
lunacm:>hsm ped show
 
Configured Remote PED Server IP address: 106.55.19.59
Configured Remote PED Server Port: 3456
 
Ped Client Version 2.0.0 (20000)
Ped Client launched in status mode.
Callback Server is running..
 
Callback Server Information:
Hostname:                        local_host
IP:                              106.55.9.165
Software Version:                2.0.0 (20000)
 
Operating Information:
Admin Port:                         1501
External Admin Interface:           No
 
Callback Server Up Time:                     269788 (secs)
Callback Server Current Idle Time:           269788 (secs)
Callback Server Total Idle Time:             269788 (secs) (100%)
Idle Timeout Value:                 1800 (secs)
 
Number of PED ID Mappings:            0
 
Number of HMSs:                        1
HSM List:
Device Type:                        PCI HSM
HSM Serial Number:                  789654
HSM Firmware Version:               6.30.0
HSM Cmd Protocol Version:           18
HSM Callback IO Version:            1
HSM Callback Protocol Version:      1
HSM Up Time:                        269787 (secs)
HSM Total Idle Time:                269787 (secs) (100%)
HSM Current Idle Time:              269787 (secs)
 
Show command passed.
 
Command Result : No Error