Reset the challenge secret or password for the indicated PKI device.

An external SafeNet HSM can be USB-connected to a SafeNet Network HSM appliance for:

local backup/restore operations (SafeNet Backup HSM)

PKI bundle operations (SafeNet USB HSM)

SafeNet Network HSM does not pass PED operations and data through to an externally connected SafeNet HSM from a SafeNet PED that is connected locally to the SafeNet Network HSM.

If the external HSM is PED-authenticated, then the options for SafeNet PED connection are:

local PED connection, directly to the affected HSM, when needed, or

Remote PED connection, passed through the SafeNet Network HSM 

Note:  Support for PKI Bundles with Remote PED begins at firmware version 6.10.1 in the external HSM.

Note:  Support for locally connected Backup HSM with Remote PED,
begins at firmware version 6.10.1 in the external HSM.

Note:  Use of Remote PED with an external device is made possible when you set up with the commands
hsm ped vector init -serial <serial#_of_external_HSM>
and
hsm ped connect -serial <serial#_of_external_HSM>
before using token pki or token backup commands.  

 

Syntax

token pki resetPin -serial <token_serial_number> [-force]

Parameter Shortcut Description
-force -f

Force the action without prompting.

-serial -s Specifies the serial number of the inserted token, whose password or challenge is to be reset. Use the token pki list command to get the token serial number.

Example

lunash:> token pki resetPin -serial 475289 


Please type "proceed" to continue, anything else to abort: proceed 
Luna PED operation required to login as HSM Administrator - use Security Officer (blue) PED key. 

Please ensure that you copy the password from the Luna PED 
and that you keep it in a safe place. 


Command Result : 0 (Success)