Home >

LunaSH Command Reference Guide > LunaSH Commands > network > network show

network show

Display the network configuration, including the currently-negotiated NIC speed setting. This information is also collected in the hsm supportinfo command.

Syntax

network show

Example

lunash:>network show
 
 
   Hostname:          "mylunasa6"
   Domain:            "lab.eng.ott"
 
   IPv6 (eth0):       Disabled
   IP Address (eth0): 192.20.17.171
   HW Address (eth0): 00:15:B2:A2:46:00
   Mask (eth0):       255.255.255.0
   Gateway (eth0):    192.20.17.10
   Protocol (eth0):   Static
 
   IPv6 (eth1):       Enabled
   IP Address (eth1): 2018:1:2:3:215:b2ff:abe9:2565
   HW Address (eth1): 00:15:B2:A2:46:01
   Mask (eth1):       2018:1:2:3::/64
   Link-local (eth1): fe80::215:b2ff:abe9:2565
   Gateway (eth1):    <not set>
   Protocol (eth1):   SLAAC
 
   Name Servers:      172.20.10.20      172.16.2.14
   Search Domain(s):  <not set>
 
Kernel IP routing table
Destination     Gateway         Genmask         Flags Metric Ref    Use Iface
0.0.0.0         172.20.17.10    0.0.0.0         UG    0      0        0 eth0
172.20.17.0     0.0.0.0         255.255.255.0   U     0      0        0 eth0
 
 
Kernel IPv6 routing table
Destination                                 Next Hop                                Flags Metric Ref    Use Iface
2018:1:2:3::/64                             ::                                      UA    256    0        0 eth1
fe80::/64                                   ::                                      U     256    0        0 eth1
::/0                                        fe80::c800:5ff:fedc:8                   UGDA  1024   0        0 eth1
::1/128                                     ::                                      U     0      0        1 lo
2018:1:2:3:215:b2ff:abe9:2565/128           ::                                      U     0      0        1 lo
fe80::215:b2ff:abe9:2565/128                ::                                      U     0      0        1 lo
ff00::/8                                    ::                                      U     256    6        1 eth1
 
Link status
  eth0: Configured
Settings for eth0:
        Supported ports: [ TP ]
        Supported link modes:   10baseT/Half 10baseT/Full
                                100baseT/Half 100baseT/Full
                                1000baseT/Full
        Supports auto-negotiation: Yes
        Advertised link modes:  10baseT/Half 10baseT/Full
                                100baseT/Half 100baseT/Full
                                1000baseT/Full
        Advertised auto-negotiation: Yes
        Speed: 100Mb/s
        Duplex: Full
        Port: Twisted Pair
        PHYAD: 2
        Transceiver: internal
        Auto-negotiation: on
        Supports Wake-on: pumbg
        Wake-on: g
        Current message level: 0x00000007 (7)
        Link detected: yes
 
  eth1: Configured
Settings for eth1:
        Supported ports: [ TP ]
        Supported link modes:   10baseT/Half 10baseT/Full
                                100baseT/Half 100baseT/Full
                                1000baseT/Full
        Supports auto-negotiation: Yes
        Advertised link modes:  10baseT/Half 10baseT/Full
                                100baseT/Half 100baseT/Full
                                1000baseT/Full
        Advertised auto-negotiation: Yes
        Speed: 1000Mb/s
        Duplex: Full
        Port: Twisted Pair
        PHYAD: 1
        Transceiver: internal
        Auto-negotiation: on
        Supports Wake-on: pumbg
        Wake-on: g
        Current message level: 0x00000007 (7)
        Link detected: yes
 
 
Command Result : 0 (Success)