NAME
status sensors - Display sensor information
SYNOPSIS
lunash:> status sensors [-log]
DESCRIPTION
Displays the fan speed, temperature and voltage of the motherboard and power supply units.
Depending upon when you purchased your Luna SA appliance, the baseboard management controller firmware may be at a revision that reports more data on the power supply units than earlier BMC versions. The first example below shows the output from an earlier version of the BMC firmware. The second example shows the output from a more recent version. In this second example, the right PSU (facing the front of Luna SA) has no A/C power connected to it (it is in an audible alarm state).
OPTIONS
(Option) | Parameter | Description |
---|---|---|
-log | -l . | Show Sensors Event Logs |
SAMPLE OUTPUT
Older Unit
[myLuna] lunash:>status sensors
This command displays the fan speed, temperature and voltage of the motherboard and power supply units.
Sensor | | Reading | | Unit | | Status | | Thresholds | | | | | | | |
---|---|---|---|---|---|---|---|
Fan1A | 2800.000 | RPM | ok | 1000.000 | 2000.000 | na | na |
Fan1B | 2900.000 | RPM | ok | 1000.000 | 2000.000 | na | na |
Fan2A | 3000.000 | RPM | ok | 1000.000 | 2000.000 | na | na |
Fan2B | 2700.000 | RPM | ok | 1000.000 | 2000.000 | na | na |
Fan3A | 2900.000 | RPM | ok | 1000.000 | 2000.000 | na | na |
Fan3B | 2700.000 | RPM | ok | 1000.000 | 2000.000 | na | na |
CPU | 21.000 | degrees C | ok | na | na | 7.000 | 92.000 |
VRD | 31.000 | degrees C | ok | na | na | 90.000 | 100.000 |
PCH | 58.000 | degrees C | ok | na | na | 90.000 | 100.000 |
MEM | 56.000 | degrees C | ok | na | na | na | 105.000 |
Inlet | 19.000 | degrees C | ok | na | na | 40.000 | 50.000 |
CHA DIMM 0 | na | degrees C | ok | na | na | 87.000 | 97.000 |
CHA DIMM 1 | na | degrees C | na | na | na | 87.000 | 97.000 |
CHA DIMM 2 | na | degrees C | na | na | na | 87.000 | 97.000 |
CHB DIMM 0 | 35.000 | degrees C | ok | na | na | 87.000 | 97.000 |
CHB DIMM 1 | 35.000 | degrees C | na | na | na | 87.000 | 97.000 |
CHB DIMM 2 | na | degrees C | na | na | na | 87.000 | 97.000 |
RAM TMax | 35.000 | degrees C | ok | na | na | 87.000 | 97.000 |
MEM | 29.000 | degrees C | ok | na | na | na | 105.000 |
CPU VCORE | 1.008 | volts | ok | na | 0.632 | 1.440 | na |
VBAT | 3.244 | volts | ok | na | 2.796 | na | na |
3VSB | 3.412 | volts | ok | na | 3.092 | 3.492 | na |
3VMain | 3.412 | volts | ok | na | 3.092 | 3.492 | na |
+5V | 5.202 | volts | ok | na | 4.692 | 5.304 | na |
+12V | 11.908 | volts | ok | na | 11.284 | 12.740 | na |
PSU1_Voltage | 0x0 | discrete | 0x0200 | na | na | na | na |
PSU1_Temp | 0x0 | discrete | 0x0200 | na | na | na | na |
PSU1_Fan | 0x0 | discrete | 0x0200 | na | na | na | na |
PSU2_Voltage | 0x0 | discrete | na | na | na | na | na |
PSU2_Temp | 0x0 | discrete | na | na | na | na | na |
PSU2_Fan | 0x0 | discrete | na | na | na | na | na |
CPU_Thermtrip | 0x0 | discrete | OK | na | na | na | na |
PSU1_Present | 0x0 | discrete | 0x0200 | na | na | na | na |
PSU2_Present | 0x0 | discrete | 0x0100 | na | na | na | na |
Notes:
NR: Not Reading (Error)
0.00 RPM means fan unplugged, failed, or sensors not readable
DIMM: Dual In-Line Memory Module
PSU1: Power Supply Unit 1
PSU2: Power Supply Unit 2
Fan1, Fan2 and Fan3 are pluggable modules on the front of the appliance.
Each fan unit contains two fans: A and B.
----------- Power Supplies Status --------------
PSU1_Voltage | | OK |
PSU1_Temp | | OK |
PSU1_Fan | | OK |
PSU2_Voltage | | OK |
PSU2_Temp | | OK |
PSU2_Fan | | OK |
CPU_Thermtrip | | OK |
PSU1_Present | | OK |
PSU2_Present | | OK |
----------- Front Cooling Fans Status --------------
Fan1A | | OK | | 2800 RPM |
Fan1B | | OK | | 2900 RPM |
Fan2A | | OK | | 3000 RPM |
Fan2B | | OK | | 2700 RPM |
Fan3A | | OK | | 2900 RPM |
Fan3B | | OK | | 2700 RPM |
-------------- chassis status -----------------
System Power | : on |
Power Overload | : false |
Power Interlock | : inactive |
Main Power Fault | : false |
Power Control Fault | : false |
Power Restore Policy | : previous |
Last Power Event | : ac-failed |
Chassis Intrusion | : inactive |
Front-Panel Lockout | : inactive |
Drive Fault | : false |
Cooling/Fan Fault | : false |
Front Panel Control | : none |
Command Result : 0 (Success)
[myluna] lunash:>
Newer Unit
This command displays the fan speed, temperature and voltage of the motherboard and power supply units. Sensor | Reading | Unit |status | Thresholds -------------------------------------------------------------------------------------------- Fan1A . | 4300.000 | RPM | ok | 1000.000 | 2000.000 | na | na Fan1B . | 6300.000 | RPM | ok | 1000.000 | 2000.000 | na | na Fan2A . | 4300.000 | RPM | ok | 1000.000 | 2000.000 | na | na Fan2B . | 6000.000 | RPM | ok | 1000.000 | 2000.000 | na | na Fan3A . | 4500.000 | RPM | ok | 1000.000 | 2000.000 | na | na Fan3B . | 5900.000 | RPM | ok | 1000.000 | 2000.000 | na | na CPU . | 13.000 | degrees C | ok | na | na | 72.000 | 89.000 VRD . | 33.000 | degrees C | ok | na | na | 90.000 | 100.000 PCH . | 57.000 | degrees C | ok | na | na | 90.000 | 100.000 Inlet . | 22.000 | degrees C | ok | na | na | 39.000 | 45.000 CHA DIMM 0 . | na | degrees C | na | na | na | 87.000 | 97.000 CHA DIMM 1 . | na | degrees C | na | na | na | 87.000 | 97.000 CHA DIMM 2 . | na | degrees C | na | na | na | 87.000 | 97.000 CHB DIMM 0 . | na | degrees C | na | na | na | 87.000 | 97.000 CHB DIMM 1 . | na | degrees C | na | na | na | 87.000 | 97.000 CHB DIMM 2 . | na | degrees C | na | na | na | 87.000 | 97.000 RAM TMax . | 0.000 | degrees C | ok | na | na | 87.000 | 97.000 CPU_VCORE . | 0.928 | Volts | ok | na | 0.632 | 1.440 | na VBAT . | 3.164 | Volts | ok | na | 2.796 | na | na 3VSB . | 3.364 | Volts | ok | na | 3.092 | 3.492 | na 3VMain . | 3.364 | Volts | ok | na | 3.092 | 3.492 | na +5V . | 5.126 | Volts | ok | na | 4.692 | 5.304 | na +12V . | 11.856 | Volts | ok | na | 11.284 | 12.740 | na PSU1_Present . | 0x0 | discrete | 0x0200| na | na | na | na PSU2_Present . | 0x0 | discrete | 0x0200| na | na | na | na PSU1_+12V_value. | 12.024 | Volts | ok | 11.232 | na | na | 13.392 PSU1 Temp_value. | 41.000 | degrees C | ok | na | na | na | 115.000 PSU1 FAN_value . | 8000.000 | RPM | ok | 300.000 | na | na | na PSU2_+12V_value. | 12.024 | Volts | ok | 11.232 | na | na | 13.392 PSU2 Temp_value. | 39.000 | degrees C | ok | na | na | na | 115.000 PSU2 FAN_value . | 7300.000 | RPM | ok | 300.000 | na | na | na CPU_Thermtrip . | 0x0 | discrete | OK | na | na | na | na Notes: NR: Not Reading (Error) CR: Critical 0.00 RPM means fan unplugged, failed, or sensors not readable DIMM: Dual In-Line Memory Module PSU1: Power Supply Unit 1 PSU2: Power Supply Unit 2 Fan1, Fan2 and Fan3 are pluggable modules on the front of the appliance. Each fan unit contains two fans: A and B. ----------- Power Supplies Status -------------- CPU_Thermtrip . | OK ----------- Front Cooling Fans Status -------------- Fan1A . | OK | 4300 RPM Fan1B . | OK | 6300 RPM Fan2A . | OK | 4300 RPM Fan2B . | OK | 6000 RPM Fan3A . | OK | 4500 RPM Fan3B . | OK | 5900 RPM PSU1 FAN_value . | OK | 8000 RPM PSU2 FAN_value . | OK | 7300 RPM -------------- chassis status ----------------- System Power : on Power Overload : false Power Interlock : inactive Main Power Fault : false Power Control Fault : false Power Restore Policy : always-on Last Power Event : ac-failed Chassis Intrusion : inactive Front-Panel Lockout : inactive Drive Fault : false Cooling/Fan Fault : false Front Panel Control : none Command Result : 0 (Success) [myLuna] lunash:> [Fri Nov 2 14:49:03 2012]