token backup update firmware
Update the firmware on a backup token, using a firmware update package available on the SafeNet appliance. The package must be transferred to the SafeNet appliance by scp (individually or as a component of a system update), and you must login to the backup token as Token Administrator (using the token backup login command) or SO before the token backup update firmware command is run. The command requires no package name.
The term "token" in this case refers to removable token-format HSMs connected via SafeNet DOCK 2 and USB, or SafeNet Luna Backup HSM, connected via USB.
Before you can use this command, you must:
>Acquire the secure package update file from SafeNet and send the file to the SafeNet Luna Network HSM (using pscp or scp)
>Open the file on the SafeNet Luna Network HSM using the package update command
NOTE Firmware update is a local operation only, and is not supported remotely.
A capability update or a firmware update is meant to be applied just one time to an HSM. If you attempt to re-apply a capability update to an HSM that already has the capability installed, the system throws an error like " C0000002 : RC_GENERAL_ERROR ". A similar result occurs if you attempt to install a particular firmware update more than once on one HSM. This is expected behavior.
User Privileges
Users with the following privileges can perform this command:
>Admin
>Operator
Syntax
token backup update firmware -serial <serialnum> [-force]
Argument(s) | Shortcut | Description |
---|---|---|
-force | -f | Force the action without prompting. |
-serial <serialnum> | -s | Specifies the token serial number. |
Example
lunash:>token backup update firmware -serial 496771 CAUTION: This command updates the Token firmware. This process cannot be reversed. Type 'proceed' to continue, or 'quit' to quit now. >proceed Success Firmware updated. Command Result : 0 (Success)