status sensors
Displays the fan speed, temperature and voltage of the motherboard and power supply units.
Depending upon when you purchased your SafeNet Luna Network HSM appliance, the baseboard management controller firmware may be at a revision that reports more data on the power supply units than earlier BMC versions. The first example below shows the output from an earlier version of the BMC firmware. The second example shows the output from a more recent version. In this second example, the right PSU (facing the front of SafeNet Luna Network HSM) has no A/C power connected to it (it is in an audible alarm state).
User Privileges
Users with the following privileges can perform this command:
>Admin
>Operator
>Monitor
Syntax
status sensors [-log]
Argument(s) | Shortcut | Description |
---|---|---|
-log | -l | Show sensors event logs. |
Example
lunash:>status sensors This command displays the fan speed, temperature and voltage of the motherboard and power supply units. Sensor | Reading | Unit |status | Thresholds -------------------------------------------------------------------------------------------- Fan1A . | 3700.000 | RPM | ok | 1000.000 | 2000.000 | na | na Fan1B . | 4900.000 | RPM | ok | 1000.000 | 2000.000 | na | na Fan2A . | 3700.000 | RPM | ok | 1000.000 | 2000.000 | na | na Fan2B . | 5100.000 | RPM | ok | 1000.000 | 2000.000 | na | na Fan3A . | 3800.000 | RPM | ok | 1000.000 | 2000.000 | na | na Fan3B . | 5100.000 | RPM | ok | 1000.000 | 2000.000 | na | na CPU . | 26.000 | degrees C | ok | na | na | 95.000 | 100.000 VRD . | 28.000 | degrees C | ok | na | na | 105.000 | 110.000 PCH . | 29.000 | degrees C | ok | na | na | 99.000 | 104.000 Inlet . | 24.000 | degrees C | ok | na | na | 87.000 | 97.000 CHA DIMM 0 . | 11.000 | degrees C | ok | na | na | 87.000 | 97.000 CHA DIMM 1 . | na | degrees C | na | na | na | 87.000 | 97.000 CHB DIMM 0 . | na | degrees C | na | na | na | 87.000 | 97.000 CHB DIMM 1 . | na | degrees C | na | na | na | 87.000 | 97.000 RAM TMax . | 11.000 | degrees C | ok | na | na | na | na +12V . | 12.240 | Volts | ok | na | 11.160 | 12.900 | na +5V . | 5.250 | Volts | ok | na | 4.650 | 5.370 | na 3VMain . | 3.420 | Volts | ok | na | 3.060 | 3.540 | na 5VSB . | 5.250 | Volts | ok | na | 4.650 | 5.370 | na 3VSB . | 3.400 | Volts | ok | na | 3.060 | 3.540 | na CPU_VCORE . | 0.330 | Volts | ok | na | na | na | na VCCSA . | 1.060 | Volts | ok | na | 0.980 | 1.130 | na VCCIO . | 0.970 | Volts | ok | na | 0.880 | 1.020 | na 1V2 . | 1.250 | Volts | ok | na | 1.130 | 1.290 | na 2V5_VPP . | 2.540 | Volts | ok | na | 2.320 | 2.680 | na 1V0_PCH . | 1.010 | Volts | ok | na | 0.930 | 1.080 | na 1V5_BMC . | 1.550 | Volts | ok | na | 1.470 | 1.930 | na 1V26_BMC . | 1.270 | Volts | ok | na | 1.170 | 1.350 | na 1V8_AUX . | 1.820 | Volts | ok | na | 1.670 | 1.930 | na VBAT . | 3.220 | Volts | ok | 2.100 | 2.500 | na | na PSU1_+12V_value. | 12.360 | Volts | ok | na | 10.800 | 13.200 | na PSU1 Temp_value. | 33.000 | degrees C | ok | na | na | 50.000 | na PSU1 FAN_value . | 4600.000 | RPM | ok | 1000.000 | 1300.000 | na | na PSU2_+12V_value. | 0.000 | Volts | CR * | na | 10.800 | 13.200 | na PSU2 Temp_value. | 0.000 | degrees C | ok | na | na | 50.000 | na PSU2 FAN_value . | 0.000 | RPM | NR * | 1000.000 | 1300.000 | na | na PSU1_Status . | 0x0 | discrete | 0x0180| na | na | na | na PSU2_Status . | 0x0 | discrete | 0x0080| na | na | na | na CPU_Thermtrip . | 0x0 | discrete | 0x0080| na | na | na | na Watchdog . | 0x0 | discrete | 0x0080| na | na | na | na Notes: NR: Not Reading (Error) CR: Critical 0.00 RPM means fan unplugged, failed, or sensors not readable DIMM: Dual In-Line Memory Module PSU1: Power Supply Unit 1 PSU2: Power Supply Unit 2 Fan1, Fan2 and Fan3 are pluggable modules on the front of the appliance. Each fan unit contains two fans: A and B. ----------- Power Supplies Status -------------- PSU1_Status . | Presence detected PSU2_Status . | Presence detected CPU_Thermtrip . | OK Watchdog . | OK ----------- Front Cooling Fans Status -------------- Fan1A . | OK | 3700 RPM Fan1B . | OK | 4900 RPM Fan2A . | OK | 3700 RPM Fan2B . | OK | 5100 RPM Fan3A . | OK | 3800 RPM Fan3B . | OK | 5100 RPM PSU1 FAN_value . | OK | 4800 RPM PSU2 FAN_value . | OK | 4800 RPM -------------- chassis status ----------------- System Power : on Power Overload : false Power Interlock : inactive Main Power Fault : false Power Control Fault : false Power Restore Policy : previous Last Power Event : ac-failed Chassis Intrusion : inactive Front-Panel Lockout : inactive Drive Fault : false Cooling/Fan Fault : true Sleep Button Disable : not allowed Diag Button Disable : not allowed Reset Button Disable : allowed Power Button Disable : allowed Sleep Button Disabled: false Diag Button Disabled : false Reset Button Disabled: false Power Button Disabled: false Command Result : 0 (Success)