Resetting to Factory Condition
These instructions will allow you to restore your SafeNet Luna Network HSM to its original factory configuration. The HSM is zeroized, all partitions erased, and HSM policies are returned to their default settings. If you have performed firmware
To revert to a baseline appliance software/firmware, see Re-Imaging the Appliance to Factory Baseline.
To roll back the HSM firmware to the previous version, see Rolling Back the SafeNet Luna HSM Firmware.
Prerequisites
>Only the HSM SO can perform factory reset.
>You must access LunaSH via a serial console to execute hsm factoryreset.
To reset the HSM to factory condition
1.Login as HSM SO.
lunash:> hsm login
2.Reset the HSM to factory settings.
lunash:> hsm factoryreset
3.Reset the appliance configuration (network settings, ssh, ntls, etc.) to factory settings.
lunash:> sysconf config factoryreset -service all
4.Reboot the appliance.